3-74
3.2 Messages and Actions
NOTE 1: The refreshing backup can be restored
(See Section 3.4)
.
E-4395
A communication error occurred
between the image processing
section and image generating
section.
Restart the system. If problems
persist, consult your technical
representative.
No response for the demand is
obtained from the image creation
block.
Restart the system software. If the
same error occurs again, reinstall the
system software. (NOTE 1)
I-4396
Center memory space is insufficient.
Please wait.
If this error persists, consult your
technical representative.
Faulty system software
Restart the system software. If the
same error occurs again, reinstall the
system software. (NOTE 1)
E-4398
Starting-up of the scanner section
failed.
Restart the system. If problems
persist, consult your technical
representative.
Faulty system software
Restart the system software. If the
same error occurs again, reinstall the
system software. (NOTE 1)
E-4399
A failure occurred in the memory of
the image processing section.
You may print now, but several
functions may be restricted.
If this error persists, consult your
technical representative.
Center memory standard mounting
size (1GByte) cannot be assured.
(Cause of the error message)
1. Only one mounted DIMM
2. Second DIMM not inserted in Slot
2
3. Second DIMM not detected
1. Add the DIMM.
2. Insert the second DIMM correctly
in Slot 2.
3. Insert the second DIMM correctly
in Slot 2.
E-4401
A time-out error occurred during the
CTB circuit board command was
issued.
Restart the system. If problems
persist, consult your technical
representative.
No response obtained as against
command to CTB23 circuit board
(Causes of the error message)
1. Software overload (faulty software)
2. Poorly connected or broken
harness
3. Faulty CTB23 circuit board
4. Faulty GIA23 circuit board
5. Faulty GMB23 circuit board
1. Restart the system software.
2. Reconnect the connector, or repair
or replace the harness.
3. Replace the circuit board.
4. Replace the circuit board.
5. Replace the circuit board.
E-4402
A time-out error occurred during the
CLE circuit board command was
issued.
Restart the system. If problems
persist, consult your technical
representative.
No response obtained as against
command to CLE23 circuit board
(Causes of the error message)
1. Software overload (faulty software)
2. Poorly connected or broken
harness
3. Faulty CLE23 circuit board
4. Faulty GIA23 circuit board
5. Faulty GMB23 circuit board
1. Restart the system software.
2. Reconnect the connector, or repair
or replace the harness.
3. Replace the circuit board.
4. Replace the circuit board.
5. Replace the circuit board.
E-4403
A time-out error occurred during the
CPZ circuit board command was
issued.
Restart the system. If problems
persist, consult your technical
representative.
No response obtained as against
command to CPZ23 circuit board
(Causes of the error message)
1. Software overload (faulty software)
2. Poorly connected or broken
harness
3. Faulty CPZ23 circuit board
4. Faulty GIA23 circuit board
5. Faulty GMB23 circuit board
1. Restart the system software.
2. Reconnect the connector, or repair
or replace the harness.
3. Replace the circuit board.
4. Replace the circuit board.
5. Replace the circuit board.
E-4404
A time-out error occurred during the
GIA circuit board command was
issued.
Restart the system. If problems
persist, consult your technical
representative.
No response obtained as against
command to GIA23 circuit board
(Causes of the error message)
1. Software overload (faulty software)
2. Poorly connected or broken
harness
3. Faulty GIA23 circuit board
1. Restart the system software.
2. Reconnect the connector, or repair
or replace the harness.
3. Replace the circuit board.
No.
Message
Factor
Actions