3-52
3.2 Messages and Actions
E-2618
Dryer section temperature not rising.
The heaters (H760 to 767) turned off.
Shut down scanner with emergency
stop button and restart it. If problems
persist, consult your technical
representative.
Dryer section temperature does not
rise more than 1 °C in a minute at
heat up.
(Causes of the error message)
1. Cover around the dryer section is
open.
2. Abnormal dryer heater system
3. Abnormal dryer temperature
sensor
4. Abnormal dryer fan system
E-2619
P1 processing tank temperature is
out of range.
The heaters (H700 to H703) turned
off.
Shut down scanner with emergency
stop button and restart it. If problems
persist, consult your technical
representative.
P1 temperature is abnormal.
(Causes of the error message)
1. Abnormal heater system
2. Abnormal temperature sensor
system
3. Abnormal circulation system
E-2620
P2 processing tank temperature is
out of range.
The heaters (H700 to H703) turned
off.
Shut down scanner with emergency
stop button and restart it. If problems
persist, consult your technical
representative.
P2 temperature is abnormal.
(Causes of the error message)
1. Abnormal heater system
2. Abnormal temperature sensor
system
3. Abnormal circulation system
E-2621
PS1/2/3 processing tank temperature
is out of range.
The heaters (H700 to H703) turned
off.
Shut down scanner with emergency
stop button and restart it. If problems
persist, consult your technical
representative.
PS1/2 temperature is abnormal.
(Causes of the error message)
1. Abnormal heater system
2. Abnormal temperature sensor
system
3. Abnormal circulation system
E-2622
PS4 processing tank temperature is
out of range.
The heaters (H700 to H703) turned
off.
Shut down scanner with emergency
stop button and restart it. If problems
persist, consult your technical
representative.
PS3/4 temperature is abnormal.
(Causes of the error message)
1. Abnormal heater system
2. Abnormal temperature sensor
system
3. Abnormal circulation system
E-2623
Dryer section temperature is out of
range.
The heaters (H760 to 767) turned off.
Shut down scanner with emergency
stop button and restart it. If problems
persist, consult your technical
representative.
Dryer section temperature is
abnormal.
(Causes of the error message)
1. Abnormal dryer heater system
2. Abnormal dryer temperature
sensor system
3. Abnormal dryer fan system
E-2624
P1 safety thermostat (D700)
activated.
The heaters (H700 to H703) turned
off.
Shut down scanner with emergency
stop button and restart it. If problems
persist, consult your technical
representative.
Safety thermostat in the P1
processing tank is activated.
(Causes of the error message)
1. Abnormal heater system
2. Abnormal temperature sensor
system
3. Abnormal circulation system
4. Abnormal heater safety thermostat
system
No.
Message
Factor
Actions