7-25
7.1 Auto Film Carrier NC100AY (Pressure Cover Section)
7
Installation
Installation is essentially in the reverse order of
removal.
NOTE: • Attach two new adhesive tapes to the new flexible
cable by referring the tape positions on the
removed cable.
• Insert the flexible cable into the connector so that
its blue contact area disappears.
• Attach the flexible cable to the circuit board cover
so that its crease is 3mm in front of the cover edge
as shown.
1. Install the carrier to the scanner.
2. Open the Menu 0443 “NC100AY Sensor
Calibration Information” screen.
3. Click the [RUN] button.
• The sensors are calibrated and their data are
displayed.
4. Click the [FlashROM Writing] button.
5. Click the [OK] button.
• Data are written into the FlashROM on the
CYA23 circuit board.
6. Click the [HD Writing] button.
• Data are written into the HD of the main control
unit.
7. Click the [Close] button.
Z
2
484
Flexible Cable
Cover
3mm
7.1.18
Machine Data Writing