5-116
5.6 Printer Adjustment/Maintenance (05)
This procedure sets up daily calibration of the
sensors.
[Selection]
[Setup and Maintenance]
→
[05 Printer Adjustment/
Maintenance]
→
[0559 Sensor Calibration (Daily)]
• The calibration history is displayed in the lower box
of the screen.
D619 : Upper magazine splice sensor
D629 : Lower magazine splice sensor
D650 : Exposure section entrance paper sensor.
D653 : Exposure position paper sensor
1. Select “Yes” for “Daily Calibration” normally.
NOTE: Manual calibration can be used if “No” is
selected.
2. Click the [Set] button.
3. Click the [Close] button.
• Operation returns to the menu screen.
<Electric Current Calibration for Sensors not to
be Calibrated Daily>
1. Select a sensor in the “Sensor No.” box.
2. Click the [Set] button.
3. Click the [Close] button.
• Operation returns to the menu screen.
5.6.26
Sensor Calibration (Daily) (0559)