7-64
7.3 NC100AY Nest Section
Installation
Installation is essentially in the reverse order of
removal.
NOTE: • Insert an unexposed film cartridge, align the
detecting arm with the rear edge of the sensor and
tighten the screws.
• Check that unexposed film cartridges are detected
correctly by following the <Detection Inspection>
below.
<Detection Inspection>
1) Install the carrier to the SP-3000 and insert an
unexposed IX240 film cartridge.
2) Proceed to the Menu 0421 “NC100AY Input
Check” screen.
3) Make sure “IPI sensor (D121)” is “Unexposed”.
If it is “Unexposed”, proceed to Step 4) below.
If it is “Exposed”, proceed to <Detection
Adjustment>.
Z
2
356
Detecting Arm
Sensor
Screw
Z
2
576
Unexposed Film Cartridge