13-9
13.1 Distribution Entrance Unit
13
4. Remove the two screws mounting the unit.
5. Remove the distribution entrance unit.
Reinstallation
Reinstallation is essentially in the reverse order of
removal.
NOTE: After unit installation, perform the gear engagement
adjustment described below.
<Gear Engagement Adjustment>
1. Align the unit with the rail, slide it in place and
secure with the screw.
2. Loosen the screw and remove the jig.
3. Loosen the screw securing the gear bracket.
4. Install the jig between the gear shafts and tighten
the screw.
5. Remove the jig and return it to its original position.
LII489
Unit
Screws (2)
LII515
Rail
Unit
LII516
Screw
Tool
Gear Bracket
Screw