11-14
11.1 Cutter/Feed Section
Removal
1. Remove the connector cover
2. Open the six clamps and disconnect the three
connectors (M600, Jha3 and Jha5).
3. Remove the seven screws and then the cutter unit.
Reinstallation
Reinstallation is essentially in the reverse order of
removal.
NOTE: • Align the notch in the bracket with the tab on the
cutter unit and tighten the seven screws.
• The connector codes “jha3” or “jha6”, “jha4” or
“jha7” or “jha5” or “jha8” is found on each surface
of the code tag because the upper and lower cutter
units are the same parts.
• After installation, perform the following
adjustments.
1) Menu 0558 "Sensor Calibration (Initial)"
2) Menu 0553 "Feeding Position Sensor Fine
Adjustment"
3) Menu 0554 "Image Position Initial Setting"
11.1.12
Upper Cutter Unit Removal/Reinstallation
LII039
Clamps(6)
Connectors(3)
LII040
Screws (7)