15-12
15.2 Processing solution Heater/Circulation Pump Section
6. Loosen the four screws and remove the drain
cocks from the brackets.
7. Loosen the two screws and remove the pump
bracket.
8. Disconnect the four pump connectors and open
the seven harness clamps.
9. Remove the two screws securing the pump.
10. Loosen the two clamps and disconnect the inlet
and outlet hoses from the pump.
Installation
Installation is essentially in the reverse order of removal.
NOTE: Connect the hoses securely
LII681
Screws (4)
Drain Cocks (4)
Screws (2)
Pump Bracket
LII682
Connectors (4)
Clamps (7)
LII683
Screws (2)
Clamps (2)
Hose
Pump (PU702)
Pump (PU703)
Pump (PU704)
Pump (PU705)