3-99
3.2 Messages and Actions
3
NOTE 1: The refreshing backup can be restored (see Section 3.4).
E-4620
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-task start error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4621
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-serial Transmission Driver 3
parity error
(Causes of the error message)
1. Noise in electric line
- Outside noise (static electricity,
radio transmission or power
supply-induced)
- Inside noise
2. System software overload (faulty
software)
3. Faulty CLE23 circuit board (CPU)
1. Click [OK] to clear the message.
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
3. Replace the circuit board.
E-4622
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-serial Transmission Driver 3
framing error
(Causes of the error message)
1. Noise in electric line
- Outside noise (static electricity,
radio transmission or power
supply-induced)
- Inside noise
2. System software overload (faulty
software)
3. Faulty CLE23 circuit board (CPU)
1. Click [OK] to clear the message.
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
3. Replace the circuit board.
E-4623
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-serial Transmission Driver 3
parity and framing error
(Causes of the error message)
1. Noise in electric line
- Outside noise (static electricity,
radio transmission or power
supply-induced)
- Inside noise
2. System software overload (faulty
software)
3. Faulty CLE23 circuit board (CPU)
1. Click [OK] to clear the message.
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
3. Replace the circuit board.
E-4624
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-serial Transmission Driver 3
overrun error
(Causes of the error message)
1. Noise in electric line
- Outside noise (static electricity,
radio transmission or power
supply-induced)
- Inside noise
2. System software overload (faulty
software)
3. Faulty CLE23 circuit board (CPU)
1. Click [OK] to clear the message.
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
3. Replace the circuit board.
No.
Message
Factor
Actions