2-14
2.3 Maintenance and Inspection Procedures
1. Remove the crossover racks.
2. Wipe grease off the helical drive gears fitted on
each rack.
3. Apply recommended grease to the helical drive
gears.
Recommended Grease:
Minilab Grease (P/N: 891G02003)
4. Reinstall the crossover racks.
1. Open the dryer unit and support it with Stopper 2
(yellow).
2. Remove the No.1 to No.3 crossover and dryer
entrance racks.
3. Check the auto washing nozzles for clogging and
clean them using a toothbrush if necessary.
4. Reinstall the dryer entrance and No.1 to No.3
crossover racks.
5. Close the dryer unit.
2.3.19 Processing Rack Helical Drive Gear Lubrication
L
2
939
Rack Drive Gears (6)
GREASE
2.3.20 Crossover Rack/Dryer Entrance Rack Auto Washing Nozzle
Inspection
L
2
940
Auto Washing
Nozzle
Auto Washing Nozzle
Toothbrush
Toothbrush