5-50
5.4 Scanner Adjustment/Maintenance (03)
This procedure checks the status of the carrier
inclination.
NOTE: If the difference value is more than 100, inspect the
film carrier.
[Selection]
[Setup and Maintenance]
→
[03 Scanner Adjustment/
Maintenance]
→
[0342 Carrier Inclination Display]
1. Insert a film into the carrier or install the focusing
chart jig.
2. Click the [135] or [120] button.
• The auto focusing is started and the position of
the vertical and horizontal focusing pulses of the
carrier and difference value between the
maximum and minimum positions are displayed.
3. Click the [Close] button.
• Operation returns to the menu screen.
5.4.8
Carrier Inclination Display (0342)
Z
2
212
Focusing Chart Jig