3-161
3.2 Messages and Actions
3
W-7211
The feeding lane position sensor
(D129) failed.
The 135 feeding lane cannot be
used.
(Causes of the error message)
1. Foreign matter blocking 135/IX240
feed lane position sensor (D129/
D130)
2. Faulty feed lane position sensor
(D129/D130)
3. Poorly connected or broken
harness
4. Faulty CYA23 circuit board
1. Remove the foreign matter.
2. Replace the sensor.
3. Reconnect or replace the harness.
4. Replace the circuit board.
W-7212
The feeding lane position sensor
(D130) failed.
The IX240 feeding lane cannot be
used.
(Causes of the error message)
1. Foreign matter blocking 135/IX240
feed lane position sensor (D129/
D130)
2. Faulty feed lane position sensor
(D129/D130)
3. Poorly connected or broken
harness
4. Faulty CYA23 circuit board
1. Remove the foreign matter.
2. Replace the sensor.
3. Reconnect or replace the harness.
4. Replace the circuit board.
I-7213
Downloading the data to the carrier.
Please wait a moment.
It takes about 40 seconds.
Updating data from HDD to
FlashROM
Wait until downloading is completed.
I-7214
Uploading the data from the carrier.
Please wait a moment.
It takes about 40 seconds.
Taking more than 3 seconds to
upload data from carrier
Wait until uploading is completed.
W-7215
The version information stored in the
hard disk was not known.
The version may be old, but you can
use the current carrier.
Carrier program file in HDD may not
exist or be damaged.
Restart the system software.If the
error occurs again, reinstall the
system software (NOTE1)
W-7216
The feeding lane of the carrier was
switched to the intermediate position.
Remove carrier and then film.
(Causes of the error message)
1. Feed lane changed during
scanning
2. Faulty feed lane change lock parts
3. Faulty feed lane position sensor
(D129/D130) or harness
4. Faulty CYA23 circuit board
1. Do not change the feed lane
during scanning.
2. Replace the damaged parts.
3. Replace the sensor or harness.
4. Replace the circuit board.
W-7217
Changing of the IX240 cartridge lever
was detected.
Remove the carrier, and then take out
the cartridge.
(Causes of the error message)
1. Release button pressed during
scanning
2. Cartridge lever returned by it self
during scanning
3. Faulty cartridge set sensor (D123)
or harness
4. Faulty CYA23 circuit board
1. Do not press the release button
during scanning.
2. Replace the cartridge lever or
lever lock parts.
3. Replace the sensor or harness.
4. Replace the circuit board.
I-7218
Too many frames in film.
Printing is possible up to 79th frame.
(Causes of the error message)
80 or more frames were detected
during scanning.
Reduce the frames to 79 and below.
No.
Message
Factor