3-7
3.2 Messages and Actions
3
NOTE 1: The refreshing backup can be restored (see Section 3.4).
W-1512
The FD free space insufficient.
Insert the correct floppy disk into the
FD drive.
Inserted FD is full.
(Causes of the error message)
1. Inserted floppy disk is full.
2. Faulty floppy disk drive
1. Insert a blank disk.
2. Replace the main control unit.
W-1513
An unsettled order exists.
Settle the order.
Unsorted prints remain after printing.
Press [Sort].
W-1521
PU800B is not turned ON or is
disconnected.
Check the connection with PU800B,
press the [Retry] button.
Communication error occurred in
downloading from PU800B.
(Causes of the error message)
1. PU800B turned OFF
2. Connection error or disconnection
of PU800B communication cable
1. Turn ON PU800B.
2. Connect cable correctly, or replace
it.
W-1522
PU800B is not turned ON or is
disconnected.
Check the connection with PU800B,
press the [Retry] button.
Communication error occurred in
uploading to PU800B.
(Causes of the error message)
1. PU800B turned OFF
2. Connection error or disconnection
of PU800B communication cable
1. Turn ON PU800B.
2. Connect cable correctly, or replace
it.
W-1523
PU800B is not turned ON or is
disconnected.
Check the connection with PU800B,
press [Retry] to retry.
To stop printing of the price table,
press the [Stop] button.
Communication error occurred in
sending PU800B bill.
(Causes of the error message)
1. PU800B turned OFF
2. Connection error or disconnection
of PU800B communication cable
1. Turn ON PU800B.
2. Connect cable correctly, or replace
it.
W-1524
Couldn’t read the backup data for
PU800B.
Check the connection with PU800B.
File reading error occurred in
downloading from PU800B.
(Causes of the error message)
1. System software failure
2. Main control unit failure
1. Restart system, and if problem
persists, reinstall system software.
(NOTE 1)
2. Replace main control unit.
W-1525
Couldn’t write to the backup data for
PU800B.
Check the connection with PU800B.
File writing error occurred in
uploading to PU800B.
(Causes of the error message)
1. System software failure
2. Main control unit failure
1. Restart system, and if problem
persists, reinstall system software.
(NOTE 1)
2. Replace main control unit.
I-1526
Production information log file not
found.
A new file will be created.
Production information log file
reading error
Check that the production information
log file exists.
W-1527
Production information cannot be
written into file.
To use this function, consult your
technical representative.
Error occurred in writing production
information log file.
(Causes of the error message)
1. System software failure
2. Main control unit failure
1. Restart system, and if problem
persists, reinstall system software.
(NOTE 1)
2. Replace main control unit.
E-1530
FDi device registration failed.
Couldn’t provide the service.
Consult your technical representative.
Error in registering F-DIA logical
output devices (cannot be recovered)
(Causes of the error message)
1. No logical output/input device
name in registry.
2. Faulty Imaging Controller software.
1. Set up the logical output/input
name in Menu 0124 “DI Manager
Administrative Setting”.
2. Restart the Imaging Controller. If
the trouble is not remedied,
reinstall the software.
No.
Message
Factor