3-62
3.2 Messages and Actions
NOTE 1: The refreshing backup can be restored
(See Section 3.4)
.
I-2765
Initializing dryer.
Please wait.
Initial dryer temperature control is in
progress.
(Causes of the error message)
1. When the power is turned OFF
and ON, dryer initialization is
performed. During initialization,
printing cannot be performed.
1. Wait until dryer initialization is
completed(maximum of 5
minutes).
W-2766
Printing stopped.
During paper processing, processor
drive is stopped forcibly.
(Causes of the error message)
1. Faulty processor drive/stop button
on the operation panel
1. Replace the operation panel.
I-2767
Replenisher pump activating.
Please wait.
Replenisher pump is in operation.
(Causes of the error message)
1. Post operational check is
attempted while the replenisher
pump is in operation.
1. Wait until the replenisher pump
stops.
W-2768
Replenisher tank empty.
Operation cannot be started.
(Causes of the error message)
1. Maintenance operation is started
with replenisher tank empty.
1. Pour replenisher in the tank.
W-2769
Solution level has fallen.
Operation cannot be started.
(Causes of the error message)
1. Maintenance operation is started
with low processing tank level.
1. Recover processing tank level.
E-4201
An error occurred in the image
processing section.
Restart the system.
If problems persist, consult your
technical representative.
Image processing PC starting failure
due to lack of system resource or I/F
inconsistency with upstream program
Restart the system software.If the
error occurs again, reinstall the
system software. (NOTE1)
E-4202
An error occurred in the image
processing section.
Restart the system.
If problems persist, consult your
technical representative.
GMB start-up timeout
(Causes of the error message)
1. Poorly connected or broken 1394
interface cable
2. Image processing OS not started
up
3. Poorly inserted GIE23 circuit
board
4. Faulty GIE23 circuit board
1. Connect the cable correctly or
replace it.
2. Restart the system software.If the
error occurs again, reinstall the
system software. (NOTE1)
3. Insert the circuit board correctly in
the slot.
4. Replace the circuit board.
E-4204
A communication error occurred
between the main control section and
the image processing section.
(Correction data transfer error)
Check the print is correctly done.
Script transfer failure (DTM error
response)
(Causes of the error message)
1. Poorly connected or broken 1394
interface cable
2. Poorly inserted GIE23 circuit
board
3. Faulty GIE23 circuit board
1. Connect the cable correctly or
replace it.
2. Insert the circuit board correctly in
the slot.
3. Replace the circuit board.
E-4206
A communication error occurred
between the main control section and
the image processing section.
(Image data transfer error)
Check the print is correctly done.
Output image transfer failure (DTM
error response)
(Causes of the error message)
1. Poorly connected or broken 1394
interface cable
2. Poorly inserted GIE23 circuit
board
3. Faulty GIE23 circuit board
1. Connect the cable correctly or
replace it.
2. Insert the circuit board correctly in
the slot.
3. Replace the circuit board.
No.
Message
Factor
Actions