3-148
3.2 Messages and Actions
W-7110
Perforation rupture exists.
Frame position may not detected
correctly.
Remove carrier and then film, and
mend the rupture.
Film damage (8.2mm or longer
perforation length) was detected
(upstream/right-feed/leading end
near upstream perforation sensor).
(Causes of the error message)
1. Breaks in film
2. Film slippage due to dust or dirt
adhered to feed roller
3. Blocked film end or film caught
outside of carrier
4. Dust or dirt adhered to 135
upstream/downstream perforation
sensor (D102/D103) glass
5. Faulty 135 upstream/downstream
perforation sensor or harness
6. Faulty flexible cable
7. Faulty JNC23 circuit board
8. Faulty CYA23 circuit board
1. Correct the film.
2. Clean the roller.
3. Clear the film passage.
4. Clean the sensor glass.
5. Replace the sensor, or the
harness.
6. Reconnect or replace the cable.
7. Replace the circuit board.
8. Replace the circuit board.
W-7111
Perforation rupture exists.
Frame position may not detected
correctly.
Remove carrier and then film, and
mend the rupture.
Film damage (8.2mm or longer
perforation length) was detected
(upstream/right-feed/leading end
between upstream and downstream
perforation sensors).
(Causes of the error message)
1. Breaks in film
2. Film slippage due to dust or dirt
adhered to feed roller
3. Blocked film end or film caught
outside of carrier
4. Dust or dirt adhered to 135
upstream/downstream perforation
sensor (D102/D103) glass
5. Faulty 135 upstream/downstream
perforation sensor or harness
6. Faulty flexible cable
7. Faulty JNC23 circuit board
8. Faulty CYA23 circuit board
1. Correct the film.
2. Clean the roller.
3. Clear the film passage.
4. Clean the sensor glass.
5. Replace the sensor, or the
harness.
6. Reconnect or replace the cable.
7. Replace the circuit board.
8. Replace the circuit board.
W-7112
Perforation rupture exists.
Frame position may not detected
correctly.
Remove carrier and then film, and
mend the rupture.
Film damage (8.2mm or longer
perforation length) was detected
(upstream/right-feed/leading end
near downstream perforation sensor).
(Causes of the error message)
1. Breaks in film
2. Film slippage due to dust or dirt
adhered to feed roller
3. Blocked film end or film caught
outside of carrier
4. Dust or dirt adhered to 135
upstream/downstream perforation
sensor (D102/D103) glass
5. Faulty 135 upstream/downstream
perforation sensor or harness
6. Faulty flexible cable
7. Faulty JNC23 circuit board
8. Faulty CYA23 circuit board
1. Correct the film.
2. Clean the roller.
3. Clear the film passage.
4. Clean the sensor glass.
5. Replace the sensor, or the
harness.
6. Reconnect or replace the cable.
7. Replace the circuit board.
8. Replace the circuit board.