3-129
3.2 Messages and Actions
3
NOTE 1: The refreshing backup can be restored (see Section 3.4).
W-6003
Incorrect feeding lane.
Switch to the IX240 lane.
Magnetic information reading
diagnosis was executed with 135
feed lane.
(Causes of the error message)
1. Feed lane differs from that
specified on screen.
2. Faulty feed lane position sensor
(D129/D130)
3. Poorly connected or faulty harness
4. Faulty CYA23 circuit board
1. Change to the correct feed lane.
2. Replace the sensor.
3. Reconnect or replace the harness.
4. Replace the circuit board.
W-6004
The auto film carrier not installed.
Install the auto film carrier.
All diagnosis was executed without
carrier.
(Causes of the error message)
1. Self-diagnosis was executed
without NC100AY carrier.
1. Install the carrier and then execute
again.
W-6005
The film carrier is not operable.
Check if the carrier and mask are
installed correctly.
Diagnosis was executed on condition
that carrier cannot operate.
(Causes of the error message)
1. Faulty carrier
1. Repair the carrier.
W-6006
A film is not inserted.
Insert it.
Diagnosis was executed without film
insertion.
Insert a film correctly.
W-6008
Reading of data from the hard disk
failed.
Retry it, and if problems persist,
consult your technical representative.
HDD file reading failure
(Causes of the error message)
1. Faulty HDD
2. File non-existent
1. Replace the HDD.
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE1)
W-6009
Writing of data to the hard disk failed.
Retry it, and if problems persist,
consult your technical representative.
Result of diagnosis writing to HDD
failure
(Causes of the error message)
1. Lack of HDD capacity
2. Faulty HDD
1. Delete unnecessary files to assure
sufficient HDD capacity.
2. Replace the HDD.
W-6011
The diagnostics cannot be done with
the current feeding lane.
Switch to the 135 or IX240 feed lane.
Diagnosis was executed with feed
lane in neutral position.
(Causes of the error message)
1. Feed lane is in neutral position.
2. Faulty feed lane position sensor
(D129/D130)
3. Poorly connected or broken
harness
4. Faulty CYA23 circuit board
1. Change to the correct feed lane.
2. Replace the sensor.
3. Reconnect or replace the harness.
4. Replace the circuit board.
W-6013
Reading or writing of data from/to the
hard disk failed.
Retry it, and if problems persist,
consult your technical representative.
Writing to FD failure
(Causes of the error message)
1. Abnormal FD
2. Lack of FD capacity
3. Write-protect FD
4. Unformatted FD
1. Replace the FD.
2. Replace the FD with a new one.
3. Flip the write-protect tab to “write
enable”.
4. Format the FD.
W-6015
Deleting of the file failed.
If problems persist at the next start-
up, consult your technical
representative.
File EzPcErr.bak deletion failure
Clear the massage and continue
operation.
Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE1)
W-6016
Renaming of the file failed.
If problems persist at the next start-
up, consult your technical
representative.
File EzPcErr.log rename failure
Clear the massage and continue
operation.
Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE1)
No.
Message
Factor
Actions