3.2 Messages and Actions
NOTE 1: The refreshing backup can be restored
(See Section 3.4)
.
W-1422
A communication error occurred
between the main control section and
printer processor.
“No response” is received from
printer at the start-up of the post-
operational check.
(Causes of the error message)
1. Connection error or disconnection
of 1394(interface) cable or
grounding wire
2. Abnormal system software
1. Connect cable correctly, or replace
it.
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
E-1425
Initializing of printer processor failed.
Consult your technical representative.
[S-alone]: Starts only the scanner.
[End]: Shuts down the system.
[Retry]: Retries to initialize the printer.
If you restart the system, please wait
12 seconds and then turn on the
power switch.
Please wait 12 seconds, and then
turn on the system.
(Causes of the error message)
1. Abnormal system software
2. Faulty main control unit
1. Reinstall system software.
(NOTE 1)
2. Replace main control unit.
W-1427
A communication error occurred
between the main control section and
printer processor.
Check the connection, and then
press the [Retry] button.
Error returned when the printer status
notice registering command is issued
at start-up.
(Causes of the error message)
1. Connection error or disconnection
of 1394(interface) cable or
grounding wire
2. System software failure
1. Connect 1394 cable correctly or
replace it.
2. Restart system, and if problem
persists, reinstall system software.
(NOTE 1)
W-1428
A communication error occurred
between the main control section and
printer processor.
Check the connection, and then
press the [Retry] button.
Error returned when the magazine
status retrieving command is issued
to printer at start-up.
(Causes of the error message)
1. Connection error or disconnection
of 1394(interface) cable or
grounding wire
2. System software failure
1. Connect 1394 cable correctly or
replace it.
2. Restart system, and if problem
persists, reinstall system software.
(NOTE 1)
W-1449
No valid frame detected during frame
detection.
Do the pre-scan again.
Number of detected frames was zero
during frame detection.
(Causes of the error message)
1. Optical path interrupted during
bright correction at pre-operational
check
2. Lamp burned out.
3. CCD unit system abnormal
1. Perform scanner correction at pre-
operational check.
2. Replace lamp.
3. Replace the CCD unit.
W-1450
Error occurred while reading
magnetic information.
Clean the magnetic head and then try
pre-scan again.
Magnetic information reading error
(Causes of the error message)
1. Pressure cover not closed
completely.
2. Dust or debris collect on the
magnetic head.
3. Connector’s connection error or
harness disconnection in carrier.
4. MRH23(read head) circuit board
malfunction
5. CYA23 circuit board malfunction
1. Close cover.
2. Clean or replace magnetic head.
3.
4.
5.