NOTE 1: The refreshing backup can be restored (see Section 3.4).
I-4831
Detecting of the gray pixels is
completed.
Detecting gray pixels is completed.
Click [OK].
W-4832
Carrier is not installed correctly.
Check the carrier.
Carrier differs from the one installed
when executing.
(Causes of the error message)
1. Incorrect carrier installed
2. Damaged data in carrier
1. Install the correct carrier.
2. Replace the CYA23 circuit board
E-4833
Updating of the circuit board
parameter files failed.
CXX circuit board parameter file
update failure
(Causes of the error message)
1. Faulty software
1. Restart the system software.If the
error occurs again, reinstall the
system software (NOTE1)
W-4834
The dark correction failed.
Darkness correction failure
(Causes of the error message)
1. Faulty GIA23 circuit board
1. Replace the circuit board.
E-4836
A file accessing error occurred.
File access error
(Causes of the error message)
1. Lack of HDD capacity
1. Delete unnecessary files, template
and log files.
I-4837
The focus position adjustment data
deleted.
Try the focus position adjustment
again.
Downstream data are deleted at the
time of focus calibration data
registration.
Perform the focus position
adjustment again.
I-4838
The data for the optical magnification
calibration, focus calibration and the
focus position adjustment are
cleared.
Perform the optical magnification
calibration again.
After lens registration
Perform the optical magnification
calibration, focus calibration and then
the focus position adjustment.
I-4839
The focus calibration data and the
focus position adjustment data are
cleared.
Perform the focus calibration again.
After optical magnification calibration
registration
Perform the focus calibration and
focus position adjustment again.
W-4840
An incorrect diffusion box is installed.
Install the 135 diffusion box.
135 diffusion box not installed
(Causes of the error message)
1. 120 diffusion box is installed.
2. Diffusion box not installed
3. Faulty diffusion box sensor
4. Faulty diffusion box sensor
harness
1. Install the 135 diffusion box.
2. Install the 135 diffusion box.
3. Replace the sensor.
4. Reconnect or replace the harness.
W-4841
Adjusting of LED light amount failed.
LED light amount adjustment failure
(Causes of the error message)
1. Faulty harness between GIA23
and CLE23 circuit boards
1. Reconnect or replace the harness.
W-4842
Diffusion box is not installed.
Install the diffusion box.
Diffusion box not installed
(Causes of the error message)
1. Diffusion box not installed or
improperly seated
2. Faulty diffusion box sensor
3. Faulty diffusion box sensor
harness
1. Install the diffusion box correctly.
2. Replace the sensor.
3. Reconnect or replace the harness.
W-4843
The film mask is installed in the
carrier.
Remove the film mask.
Mask is installed.
Remove the mask.
No.
Message
Factor
Actions