15.2 Processing solution Heater/Circulation Pump Section
6. Open the clamp and disconnect the heater
connector.
7. Remove the two screws and then the safety
thermostat.
8. For P1/P2: Pinch the inlet and outlet hoses with
the two pinchcocks.
9. Remove the two screws and then the heater.
10. Loosen the two hose clamps and disconnect the
hoses from the heater.
Installation
Installation is essentially in the reverse order of removal.
NOTE: Connect the hoses securely
Removal
1. Remove:
• Upper connector cover
• Heater cooling fan
2. Remove the two screws securing the upper
connector bracket.
3. Open the four harness clamps.
4. Loosen the two screws and move the lower
connector bracket to one side.
LII659
Clamp
Connector
LII660
Screws (2)
Safety Thermostat
Pinchcocks (2)
Outlet Hose
Inlet Hose
Screws (2)
Heater
Clamps (2)
15.2.5
P1/P2 Circulation Pump (PU700/PU701) Replacement
LII657
Screws (2)
Upper Connector Bracket
Clamps (4)
Screw (Loosen)
Screw (Loosen)