3-123
3.2 Messages and Actions
3
I-4856
Select the correct mask type for the
bright correction table to be created.
Set the 135F mask or 135H mask.
NC100AY carrier 135F or 135H mask
selection for brightness correction
table creation
Select either one.
W-4857
Carrier is not installed.
Install the carrier.
Carrier is not installed.
Install the carrier.
W-4858
The auto correction failed.
Adjust mask position using the
adjustment button.
Mask position adjustment edge
detection error
(Causes of the error message)
1. Foreign matter in light path
2. No lower mask in NC100AY
3. 135H is selected with 135F mask
installed in NC100AY
4. 135F is selected with 135H mask
installed in NC100AY
1. Remove the foreign matter.
2. Install the lower mask.
3. Perform again with the correct
condition.
4. Perform again with the correct
condition.
W-4859
The correction value exceeds the
range.
Adjust mask position using the
adjustment button.
Mask position adjustment frame out
of range
(Causes of the error message)
1. Misaligned optical axis
2. Misaligned carrier optical axis
3. Incorrectly set mount frame
4. Faulty horizontal position control
springs of mount mask
1. Adjust the optical axis.
2. Replace the carrier or mask.
3. Insert the mount frame correctly.
4. Replace the mount mask.
W-4860
Film mask is not installed.
Install a film mask.
Mask is not installed in MFC10AY
carrier.
Install the mask.
W-4862
The sliding stage is not installed.
Install it.
MFC10AY mask table slider is not
set.
(Causes of the error message)
1. Mask table not locked in optical
axis side
2. Faulty mask table slider position
sensor (D486)
1. Move the mask table to the lock
position.
2. Replace the sensor.
I-4863
All bright correction tables cleared.
Perform the bright correction.
After LED light amount adjustment
Perform the brightness correction
again.
W-4864
The feeding lane is not set to correct
position.
Set to 135 position or IX240 position.
Lane of NC100AY carrier is not
detected.
(Causes of the error message)
1. Neutral feed lane
2. Faulty feed lane position sensor
(D129/D130)
3. Faulty harness
4. Faulty CYA23 circuit board
1. Change the lane correctly.
2. Replace the sensor.
3. Reconnect or replace the harness.
4. Replace the circuit board.
W-4865
Mount mask is not installed.
Install the mount mask.
Mount mask is required but another
mask is installed.
(Causes of the error message)
1. No mount mask or incorrect one
2. Faulty mask sensor
1. Install the correct mount mask.
2. Replace the MSB23 circuit board.
W-4866
The film will be ejected because of
switching of the operation mode.
Set the film in the carrier again.
Film ejected at focus position
adjustment due to 135F/135H
change.
(Causes of the error message)
1. Mask type changed after film
inserted
1. Select the mask type before
inserting a film.
I-4867
Performing the Optical magnification
calibration.
Execution of optical magnification
calibration
Wait until calibration is completed.
I-4868
Adjusting LED light amount.
Execution of LED light amount
adjustment
Wait until adjustment is completed.
No.
Message
Factor
Actions