3.2 Messages and Actions
W-7134
Feeding of film failed.
Remove carrier and then film.
Perforation error range exceeds
±5mm when correcting feed at
perforation decision (upstream/right-
feed/trailing end near downstream
perforation sensor).
(Causes of the error message)
1. Film slippage due to dust or dirt
adhered to feed roller
2. Blocked film end or film caught
outside of carrier
3. Dust or dirt adhered to 135
upstream/downstream perforation
sensor (D102/D103) glass
4. Faulty 135 upstream/downstream
perforation sensor or harness
5. Faulty flexible cable
6. Faulty JNC23 circuit board
7. Faulty CYA23 circuit board
1. Clean the roller.
2. Clear the film passage.
3. Clean the sensor glass.
4. Replace the sensor, or the
harness.
5. Reconnect or replace the cable.
6. Replace the circuit board.
7. Replace the circuit board.
W-7135
Feeding of film failed.
Remove carrier and then film.
Perforation error range exceeds
±5mm when correcting feed at
perforation decision (upstream/right-
feed/trailing end at right side of
downstream perforation sensor).
(Causes of the error message)
1. Film slippage due to dust or dirt
adhered to feed roller
2. Blocked film end or film caught
outside of carrier
3. Dust or dirt adhered to 135
upstream/downstream perforation
sensor (D102/D103) glass
4. Faulty 135 upstream/downstream
perforation sensor or harness
5. Faulty flexible cable
6. Faulty JNC23 circuit board
7. Faulty CYA23 circuit board
1. Clean the roller.
2. Clear the film passage.
3. Clean the sensor glass.
4. Replace the sensor, or the
harness.
5. Reconnect or replace the cable.
6. Replace the circuit board.
7. Replace the circuit board.
W-7136
Feeding of film failed.
Remove carrier and then film.
Perforation error range exceeds
±5mm when correcting feed at
perforation decision (upstream/left-
feed/trailing end at left side of frame
sensors).
(Causes of the error message)
1. Film slippage due to dust or dirt
adhered to feed roller
2. Blocked film end or film caught
outside of carrier
3. Dust or dirt adhered to 135
upstream/downstream perforation
sensor (D102/D103) glass
4. Faulty 135 upstream/downstream
perforation sensor or harness
5. Faulty flexible cable
6. Faulty JNC23 circuit board
7. Faulty CYA23 circuit board
1. Clean the roller.
2. Clear the film passage.
3. Clean the sensor glass.
4. Replace the sensor, or the
harness.
5. Reconnect or replace the cable.
6. Replace the circuit board.
7. Replace the circuit board.
No.
Message
Factor
Actions