3-125
3.2 Messages and Actions
3
NOTE 1: The refreshing backup can be restored (see Section 3.4).
W-4904
The feeding lane of the carrier was
switched.
Lane change operation detection
(Causes of the error message)
1. NC100AY feed lane changed
2. Faulty feed lane position
sensor(D129/D130)
3. Faulty harness
4. Faulty CYA23 circuit board
1. Change to the feed lane required.
2. Replace the sensor.
3. Reconnect or replace the harness.
4. Replace the circuit board.
W-4905
Changing of the cartridge was
detected.
Cartridge change operation detection
(Causes of the error message)
1. Abnormal system software
1. Restart the system software. If the
error occurs again, reinstall the
system software (NOTE1)
W-4907
A film remains in the carrier.
Film has been inserted.
Insert a film after clicking [Run]
button.
W-4908
Film is not inserted.
Film is not inserted.
Insert a film as necessary.
W-4909
The carrier type is not NC100AY.
Carrier type is not NC100AY.
Install the NC100AY carrier.
W-4910
The feeding lane is not set to IX240.
Select the IX240 lane.
Carrier is not set in IX240 feed lane.
(Causes of the error message)
1. Feed lane is not for IX240.
2. Faulty IX240 feed lane position
sensor (D130)
3. Faulty harness
4. Faulty CYA23 circuit board
1. Set in the IX240 feed lane.
2. Replace the sensor.
3. Reconnect or replace the harness.
4. Replace the circuit board.
W-4911
The feeding lane is not set to correct
position.
Set to 135 position or IX240 position.
Carrier feed lane is not in 135 or
IX240.
(Causes of the error message)
1. Feed lane not in place
2. Faulty IX240 feed lane position
sensor (D130)
3. Faulty harness
4. Faulty CYA23 circuit board
1. Set to the IX240 feed lane.
2. Replace the sensor.
3. Reconnect or replace the harness.
4. Replace the circuit board.
W-4912
The operation was cancelled.
Operation was canceled.
(Causes of the error message)
1. Clicked [Stop] button
2. Faulty keyboard
1. –
2. Replace the keyboard.
W-4913
The number of times for repeating is
not selected.
Set the number of times.
Number of repeat times not set
(Causes of the error message)
Zero or below is entered for number
of repeat times.
Enter one or higher.
W-4914
The operation is aborted.
Abnormal termination
Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
I-4915
Write the setting values to the
monitor frame ratio information file.
OK?
Setup value is written in the monitor
frame ratio file.
Click [OK].
I-4917
Write the carrier installation
information to the FlashROM.
OK?
Carrier installation information is
written in FlashROM.
Click [OK].
I-4918
Writing the information to the
FlashROM.
Please do not remove the carrier.
Writing in FlashROM
Wait until writing is completed.
W-4919
Enter numerals only for the carrier ID. (Causes of the error message)
1. Entered characters except
numerical value in carrier ID
2. Faulty keyboard
1. Enter the correct ID.
2. Replace the keyboard.
No.
Message
Factor
Actions