3-104
3.2 Messages and Actions
NOTE 1: The refreshing backup can be restored
(See Section 3.4)
.
E-4653
An error occurred during accessing of
the CLE circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-I2C slave a R/W
data sending failure 2
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4654
An error occurred during accessing of
the CLE circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-I2C receiving start error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4655
An error occurred during accessing of
the CLE circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-I2C data receiving error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4656
An error occurred during accessing of
the CLE circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-I2C final data receiving error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4657
An error occurred during accessing of
the CLE circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-I2C receiving OFF error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4658
An error occurred during accessing of
the CLE circuit board external
memory.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-EEPROM R/W error
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
W-4659
The adjustment data for the CLE
circuit board external memory is
corrupted.
Restart the system. If problems
persist, consult your technical
representative.
Use of ROM data at starting up
(Causes of the error message)
1. Faulty system software
2. Faulty CLE23 circuit board (CPU
or EEPROM)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4660
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-control task receiving error
(Causes of the error message)
1. System software overload
(faulty software)
2. Faulty CLE23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4661
The control for the CLE circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCLE-LED task receiving error
(Causes of the error message)
1. System software overload
(faulty software)
2. Faulty CLE23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
No.
Message
Factor
Actions