16-15
16.2 Processing Solution Replenishment System
16
Removal
1. Remove:
• PSR pump bracket
.
• Connector cover
2. Pinch the inlet and outlet hoses with the pinchcocks.
3. Loosen the two joint nuts.
4. Remove the screw and then the pump.
5. Turn the bellows 90 degrees counterclockwise to
remove it.
Installation
Installation is essentially in the reverse order of removal.
NOTE: After installation, perform the following adjustment.
Menu 0620 "Pump Output Measurement/Setting"
16.2.6
PSR Pump Bellows Replacement
LII707
Hoses (2)
Pinchcocks (2)
Joint Nuts (2)
LII711
Screw
Pump
LII712
Bellows