5-63
5.4 Scanner Adjustment/Maintenance (03)
5
This menu checks parameters saved in the EEPROM
of the CTB23, CLE23, CPZ23, CCD23 circuit boards
and the HD of the main control unit, then displays the
result by “OK” or “NG”.
If “NG” is displayed, the [Storage] and [Reading]
buttons become effective.
[Storage] Button:
Saves the parameters from the
circuit board into the HD when
the system software (A1) is
newly installed.
[Reading] button:
Reads the parameters saved in
the HD and writes them into the
circuit board when the circuit
board has been replaced.
[FD reading] button:
Reads the displacement
parameters from the FD and
writes them into the CPZ23
circuit board and the HD when
the CCD unit has been
replaced.
[Selection]
[Setup and Maintenance]
→
[03 Scanner Adjustment/
Maintenance]
→
[0350 Scanner Parameter Check/
Update]
●
Storage
Each button becomes effective when the system
software (A1) is newly installed.
1. Click the [Storage] button.
2. Click the [OK] button.
• The parameters in the EERROM are saved into
the HD.
3. Click the [Close] button.
• Operation returns to the menu screen.
5.4.16
Scanner Parameter Check/Update (0350)