18-10
18.1 Dryer Exit Unit
Removal
1. Remove the dryer exit unit top cover
.
2. Remove the two screws and then the print
sending unit bracket.
NOTE: Use a long shank screwdriver to avoid the
screws from damage.
3. Disconnect the three connectors (Jso6/Jso12/
Jshu3).
4. Loosen the two screws and turn the gear bracket
counterclockwise. Tighten the two screws.
18.1.3
Dryer Exit Unit Removal/Reinstallation
LII755
Screws (2)
Print Sending Unit Bracket
LII756
Connectors (3)
LII757
Screws (2) (Loosen)
Gear Bracket
“ ” Marks