7-41
7.2 NC100AY Lower Feed Section
7
Removal
1. Remove the feed section unit
2. Place the feed section unit upside down.
3. Remove the countersunk flat head screws and
then the slide rail.
Installation
Installation is essentially in the reverse order of
removal.
NOTE: The right- and left-hand slide rails should be
installed in place. The inner rail of the right-hand
slide rail is extruded 12mm when it is pulled out fully
to the front side.
Removal
1. Remove the right-hand slide rail
.
2. Remove the screw and then the sensor.
3. Disconnect the connector form the sensor.
Installation
Installation is essentially in the reverse order of
removal.
NOTE: Align the hole in the circuit board with the locating
boss.
7.2.13
Slide Rail Replacement
Z
2
315
Left-hand Slide
Rail
Right-hand Slide Rail
Countersunk Flat Head Screws (2)
Z
2
316
Left-hand Slide Rail
Inner Rail
12mm
Right-hand Slide Rail
7.2.14
Pressure Cover Open/Close Sensor (D128) Replacement
Z
2
317
Connector
Sensor (D128)
Screw