3-69
3.2 Messages and Actions
3
NOTE 1: The refreshing backup can be restored (see Section 3.4).
W-4346
Couldn’t read the bar code on the
film.
Continue processing.
Barcode cannot be read or
information delayed in one-way
mode.
(Causes of the error message)
1. Notched film or fogged film edge
2. Film without barcode information
Proceed processing and check color,
etc. on the printing screen.
W-4348
A film is not inserted into the carrier.
Insert a film, and then retry printing.
Film is not inserted when leading end
frame detecting command is
received. (Software abnormal)
Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
W-4349
A film type is not selected.
Select a film type, and then retry
printing.
Original type is not selected when
leading end frame detecting
command is received. (Software
abnormal)
Restart the system software.If the
error occurs again, reinstall the
system software. (NOTE1)
W-4351
An incorrect parameter in the CCD
circuit board.
The operation may be continued, but
if a mechanical failure or abnormal
image occurs, consult your technical
representative.
Parameter of the scanner CCD23
circuit board differs from one of the
HDD.
(Causes of the error message)
1. CCD unit has been replaced.
2. Main control unit has been
replaced.
3. Parameter writing is not performed
after the system software has
been newly installed.
4. Damaged data of circuit board or
file in HDD of main control unit
HDD.
On Menu 0350 “Scanner Parameter
Check/Update”, perform the
following.
1. Click [Reading].
2. Click [Storage].
3. Click [Storage].
4. Perform “AD Timing Adjustment”,
“OFD voltage adjustment” and
“Gray Pixel Detection”.
W-4352
An incorrect parameter in the CTB
circuit board.
Consult your technical
representative.
Parameter of the scanner CTB23
circuit board differs from one of the
HDD.
(Causes of the error message)
1. CTB23 circuit board has been
replaced.
2. Main control unit has been
replaced.
3. Parameter writing is not performed
after the system software has
been newly installed.
4. Damaged data of circuit board or
file in HDD of main control unit
HDD.
On Menu 0350 “Scanner Parameter
Check/Update”, perform the
following.
1. Click [Reading].
2. Click [Storage].
3. Click [Storage].
4. Perform “AD Timing Adjustment”,
“OFD voltage adjustment” and
“Gray Pixel Detection”.
W-4353
An incorrect parameter in the CLE
circuit board.
Consult your technical
representative.
Parameter of the scanner CLE23
circuit board differs from one of the
HDD.
(Causes of the error message)
1. CLE23 circuit board has been
replaced.
2. Main control unit has been
replaced.
3. Parameter writing is not performed
after the system software has
been newly installed.
4. Damaged data of circuit board or
file in HDD of main control unit
HDD.
On Menu 0350 “Scanner Parameter
Check/Update”, perform the
following.
1. Click [Reading].
2. Click [Storage].
3. Click [Storage].
4. Perform “AD Timing Adjustment”,
“OFD voltage adjustment” and
“Gray Pixel Detection”.
No.
Message
Factor
Actions