3-135
3.2 Messages and Actions
3
W-7031
Feeding of film failed.
Remove carrier and then film.
ATP hole length is more than 8mm at
feeding, or MTP cannot be found
after feeding 9mm from ATP.
(Causes of the error message)
1. Slipped or blocked film
2. Broken cartridge door/flange
3. Faulty nest section unit
4. Faulty IX240 winding unit
5. Dust or dirt adhered to IX240
perforation sensor (D117L/P)
glass
6. Faulty IX240 perforation sensor
(D117L/P) or harness
7. Faulty feed/supply/door motor
(M101/M102/M103)
8. Faulty IX240/135 side belt
9. Faulty harness
10.Faulty flexible cable
11.Faulty JNC23 circuit board
12.Faulty CYA23 circuit board
1. Clean the feed rollers or clear the
cause of blocking.
2. If the error occurs with a certain
cartridge, reload film into a known
good cartridge.
3. Replace the nest section unit.
4. Replace the IX240 winding unit.
5. Clean the glass.
6. Replace the sensor or harness.
7. Replace the motor.
8. Adjust or replace the belt.
9. Reconnect or replace the harness.
10.Reconnect or replace the cable.
11.Replace the circuit board.
12.Replace the circuit board.
W-7032
Feeding of film failed.
Remove carrier and then film.
Final frame has been fine adjusted
more than 11mm from DTP when
DTP position from TAP is 66mm due
to reshaping twice.
(Causes of the error message)
1. Faulty key circuit board (D131 to
D134)
2. Faulty key circuit board harness
3. Dust or dirt adhered to IX240 TAP
sensor (D116L/P) glass
4. Faulty IX240 TAP sensor (D116L/
P)
5. Faulty harness
6. Faulty flexible cable
7. Faulty JNC23 circuit board
8. Faulty CYA23 circuit board
1. Replace the circuit board.
2. Reconnect or replace the harness.
3. Clean the glass.
4. Replace the sensor.
5. Reconnect or replace the harness.
6. Reconnect or replace the cable.
7. Replace the circuit board.
8. Replace the circuit board.
W-7034
Feeding of film failed.
Remove carrier and then film.
Number of perforation edges has
been detected exceeding those
detected by MTP sensor at feeding.
(Causes of the error message)
1. Dust or dirt adhered to IX240
perforation sensor (D117L/P)
glass
2. Faulty IX240 perforation sensor
(D117L/P) or harness
3. Faulty flexible cable
4. Faulty JNC23 circuit board
5. Faulty CYA23 circuit board
1. Clean the glass.
2. Replace the sensor or harness.
3. Reconnect or replace the cable.
4. Replace the circuit board.
5. Replace the circuit board.
No.
Message
Factor
Actions
ATP = Anticipation perforation DTP = Detach perforation MTP = Metering perforation
TAP = Turnaround perforation