3-162
3.2 Messages and Actions
W-7219
A film remains at the right-hand side
of the carrier.
Remove the carrier, and then take out
the film.
Downstream perforation sensor
detects film before 135 upstream
perforation sensor. Previous right-
feed scanned film is left in the carrier
(film exists on downstream
perforation sensor).
(Causes of the error message)
1. The previously scanned film is not
removed.
2. Dust or dirt adhered to 135
downstream perforation sensor
(D103) glass
3. Faulty 135 downstream perforation
sensor (D103) or harness
4. Faulty flexible cable
5. Faulty JNC23 circuit board
6. Faulty CYA23 circuit board
1. Remove the film.
2. Clean the glass.
3. Replace the sensor, or reconnect
or replace harness.
4. Reconnect or replace the cable.
5. Replace the circuit board.
6. Replace the circuit board.
I-7220
The downloader returned the error, so the
version of the carrier was not known.
The version may be old, but you can
use the current carrier.
SDLT task tries to transfer file to GMB
but carrier version cannot be
downloaded due to 1394 error
communication.
Clear the 1394 error.
I-7221
To prevent film scratches, clean the
feeding lane.
Cleaning message to prevent flow
when inserting a reversal film after
360 or more frames are printed
consecutively.
(Causes of the error message)
1. Reversal film is inserted after more
than 360 frames are fed.
1. Clean the feed lane.
I-7222
Cartridge release button was pressed
during scanning.
After the feed-out of film, remove the
carrier, and then take out the
cartridge from it.
Cartridge release button was pressed
during IX240 scanning.
Remove the cartridge after the door
closes and the green indicator light
blinks.
No.
Message
Factor
Actions