3-137
3.2 Messages and Actions
3
W-7037
Feeding of film failed.
Remove carrier and then film.
ATP hole length is more than 8mm at
time of return or MTP cannot be
found after feeding 29mm from ATP.
(Causes of the error message)
1. Slipped film
2. Broken cartridge door/flange
3. Faulty nest section unit
4. Faulty IX240 winding unit
5. Dust or dirt adhered to IX240
perforation sensor (D117L/P)
glass
6. Faulty IX240 perforation sensor
(D117L/P) or harness
7. Faulty feed/supply/door motor
(M101/M102/M103)
8. Faulty IX240/135 side belt
9. Faulty harness
10.Faulty flexible cable
11.Faulty JNC23 circuit board
12.Faulty CYA23 circuit board
1. Clean the feed rollers
2. If the error occurs with a certain
cartridge, reload film into a known
good cartridge.
3. Replace the nest section unit.
4. Replace the IX240 winding unit.
5. Clean the glass.
6. Replace the sensor or harness.
7. Replace the motor.
8. Adjust or replace the belt.
9. Reconnect or replace the harness.
10.Reconnect or replace the cable.
11.Replace the circuit board.
12.Replace the circuit board.
W-7038
Feeding of film failed.
Remove carrier and then film.
MTP cannot be found after feeding
film 9mm from ATP.
(Causes of the error message)
1. Slipped or blocked film
2. Broken cartridge door/flange
3. Faulty nest section unit
4. Faulty IX240 winding unit
5. Dust or dirt adhered to IX240
perforation sensor (D117L/P)
glass
6. Faulty IX240 perforation sensor
(D117L/P) or harness
7. Faulty feed/supply/door motor
(M101/M102/M103)
8. Faulty IX240/135 side belt
9. Faulty harness
10.Faulty flexible cable
11.Faulty JNC23 circuit board
12.Faulty CYA23 circuit board
1. Clean the feed rollers or clear the
cause of blocking.
2. If the error occurs with a certain
cartridge, reload film into a known
good cartridge.
3. Replace the nest section unit.
4. Replace the IX240 winding unit.
5. Clean the glass.
6. Replace the sensor or harness.
7. Replace the motor.
8. Adjust or replace the belt.
9. Reconnect or replace the harness.
10.Reconnect or replace the cable.
11.Replace the circuit board.
12.Replace the circuit board.
No.
Message
Factor
Actions
ATP = Anticipation perforation MTP = Metering perforation