7-51
7.2 NC100AY Lower Feed Section
7
3. Remove the two screws securing the JNC23
circuit board.
4. Release the locks of the connectors and
disconnect the two flexible cables.
Installation
Installation is essentially in the reverse order of
removal.
NOTE: Insert the end of the flexible cable into the connector
so taht its blue contact area disappears.
Z
2
294
Screws (2)
JNC23 Circuit Board
Z
2
347
Connectors