3-63
3.2 Messages and Actions
3
NOTE 1: The refreshing backup can be restored (see Section 3.4).
E-4207
The image processing is not
operable.
Consult your technical
representative.
Conversion executed without GPA
circuit board (Convertible number
zero)
(Causes of the error message)
1. GPA23 circuit board in incorrect
slot
2. Poorly connected GPA23 circuit
board
3. Faulty GPA23 circuit board
1. Insert the GPA23 circuit board in
the correct slot.
2. Insert the circuit board correctly in
the slot.
3. Replace the circuit board.
E-4208
A communication error occurred
between the main control section and
the image processing section.
Command data transfer error.
Restart the system.
If problems persist, consult your
technical representative.
IPC error (Breaking of IEEE1394)
(Causes of the error message)
1. Poorly connected or broken 1394
interface cable
2. Poorly inserted GIE23 circuit
board
3. Faulty GIE23 circuit board
1. Connect the cable correctly or
replace it.
2. Insert the circuit board correctly in
the slot.
3. Replace the circuit board.
I-4210
Processing image.
Start it after the image processing.
Image processing
Wait until processing is completed.
E 4211
An error occurred in the image
processing section.
Check the print is correctly done.
90˚ turning/mirror image failure
(Parameter)
Click [OK] and proceed processing.
If the error occurs again, restart the
system software or reinstall it.
(NOTE1)
I-4212
Restart the system.
At the time of self diagnosis including
DIMM check
Restart the system software.
E-4213
Downloading of the red eye
correction data failed.
Restart the system. If problems
persist, consult your technical
representative.
The parameter file does not exist in
the hard disk of the main control unit.
(Causes of the error message)
1. File is deleted by mistake (such as
power OFF during writing).
2. Faulty hard disk in main control
unit
1.Reinstall A1 system software.
2.Replace the hard disk.
E-4221
The GPA circuit board not detected.
Restart the system. If problems
persist, consult your technical
representative.
DSP not detected (Faulty or no circuit
board)
(Causes of the error message)
1. GPA23 circuit board in incorrect
slot
2. Poorly inserted GPA23 circuit
board
3. Faulty GPA23 circuit board
1. Insert the GPA23 circuit board in
the correct slot.
2. Insert the circuit board correctly in
the slot.
3. Replace the circuit board.
E-4222
An error occurred in the image
processing section.
Check the print is correctly done.
HW script transfer ID obtaining failure
(Retry over/abnormal software)
Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
I-4223
The image processing of any frame
was not cancelled.
Cancel request failure (Command
cross occurred)
Click [OK] and proceed processing.
E-4224
An error occurred in the image
processing section.
Restart the system.
If problems persist, consult your
technical representative.
Pattern file transfer ID obtaining
failure
Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
No.
Message
Factor
Actions