3-48
3.2 Messages and Actions
NOTE 2: Press the densitometer reset switch.
Reset Switch (AD300)
W-2562
Detecting of leading end of the print
failed.
Insert the condition setup print into
the densitometer correctly, and
perform the measurement again.
The leading end of the print upkeep
chart cannot be detected during
density measurement.
(Causes of the error message)
1. Chart is not inserted.
2. Insufficiently inserted chart.
1. Set the chart and perform density
measurement again.
2. Set the chart and perform density
measurement again.
W-2563
Paper is inserted incorrectly.
Insert the upkeep print into the
densitometer correctly, and perform
the measurement again.
Pattern reading failed during density
measurement of upkeep chart.
(Causes of the error message)
1. Incorrect chart insertion direction
2. Tilted chart or out of lane
3. Inserted print is not for upkeep
printing.
1. Insert the chart correctly.
2. Adjust chart guides correctly.
3. Insert the print upkeep chart.
W-2564
Paper is inserted incorrectly.
Insert the condition setup print into
the densitometer correctly, and
perform the measurement again.
Pattern reading failed during density
measurement of upkeep chart.
(Causes of the error message)
1. Incorrect chart insertion direction
2. Slanted or misaligned chart
3. Inserted print is not for upkeep
printing.
1. Insert the chart correctly.
2. Adjust the chart guides correctly.
3. Insert the print upkeep chart.
W-2565
Detecting of trailing end of the print
failed.
Insert the upkeep print into the
densitometer correctly, and perform
the measurement again.
Chart is not ejected from the
densitometer.
(Causes of the error message)
1. Jammed chart in densitometer
1. Press the [Reset] button to eject
the chart. If not ejected, pull out
the chart by hand and press the
[Reset] button. (NOTE 2)
W-2566
Detecting of trailing end of the print
failed.
Insert the condition setup print into
the densitometer correctly, and
perform the measurement again.
Chart is not ejected from the
densitometer.
(Causes of the error message)
1. Jammed chart in densitometer
1. Press the [Reset] button to eject
the chart. If not ejected, pull out
the chart by hand and press the
[Reset] button. (NOTE 2)
W-2567
Ejecting of the print failed.
Insert the upkeep print into the
densitometer correctly, and perform
the measurement again.
Chart is not ejected from the
densitometer.
(Causes of the error message)
1. Jammed chart in densitometer
1. Press the [Reset] button to eject
the chart. If not ejected, pull out
the chart by hand and press the
[Reset] button. (NOTE 2)
No.
Message
Factor
Actions