W-4745
Setting of the dark correction table
failed.
Restart the system. If problems
persist, consult your technical
representative.
At the time of scanning correction or
auto darkness correction
(Causes of the error message)
1. Faulty GIA23 circuit board
1. Replace the circuit board.
W-4747
The density conversion is set to OFF
during scanning.
Restart the system. If problems
persist, consult your technical
representative.
Density conversion correction
parameter of one-way mode fine-
scanning demand is OFF.
(Causes of the error message)
1. Faulty system software
1. Restart the system software.If the
error occurs again, reinstall the
system software (NOTE1)
E-4748
The AE retry-over occurred.
Restart the system. If problems
persist, consult your technical
representative.
At the time of AF, scanner correction,
brightness correction, or AE
(Causes of the error message)
1. Faulty harness between CCD23
and GIA23 circuit boards
2. LED light amount too large
3. Faulty CCD
1. Reconnect or replace the harness.
2. Perform Menu 0349 “LED Light
Amount Adjustment”.
3. Replace the CCD unit.
E-4749
The retry-over of the DC offset
adjustment occurred.
Restart the system. If problems
persist, consult your technical
representative.
At the time of starting up, scanner
correction, darkness correction or
auto darkness correction
(Causes of the error message)
1. Faulty coaxial cable between
CCD23 and GIA23 circuit boards
2. Faulty serial transmission cable
between CCD23 and GIA23 circuit
boards
3. Faulty GIA23 circuit board
4. Faulty CCD23 circuit board
1. Reconnect or replace the cable.
2. Reconnect or replace the cable.
3. Replace the circuit board.
4. Replace the circuit board.
E-4750
The listing-up overflow occurred in
detecting the defected pixels.
Restart the system. If problems
persist, consult your technical
representative.
Gray pixels more than the specified
number of pixels were detected (Full
mode: 300 pixels, 1/4 mode: 100
pixels, 1/8 mode: 100 pixels).
(Causes of the error message)
1. Faulty CCD unit
1. Restart the system software. If the
error occurs again, replace the
CCD unit.
E-4751
The five continuous defected pixels
were found.
Restart the system. If problems
persist, consult your technical
representative.
Continuous five gray pixels in a
vertical or horizontal direction were
detected.
(Causes of the error message)
1. Faulty CCD unit
1. Restart the system software. If the
error occurs again, replace the
CCD unit.
E-4752
The listing-up overflow of defected
pixels occurred and the five
continuous defected pixels were
found.
Restart the system. If problems
persist, consult your technical
representative.
Gray pixels more than the specified
number of pixels were detected. Or
continuous five gray pixels in a
vertical or horizontal direction are
detected.
(Causes of the error message)
1. Faulty CCD unit
1. Restart the system software. If the
error occurs again, replace the
CCD unit.
E-4753
The voltage adjustment for the OFD1
failed.
Restart the system. If problems
persist, consult your technical
representative.
Condition met error judgement at the
time of OFD1 adjustment.
(Causes of the error message)
1. Faulty CCD unit
1. Restart the system software. If the
error occurs again, replace the
CCD unit.