3-107
3.2 Messages and Actions
3
NOTE 1: The refreshing backup can be restored (see Section 3.4).
E-4681
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-mail box creation error
(Causes of the error message)
1. System software overload (faulty
software)
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4682
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-alarm creation error
(Causes of the error message)
1. System software overload (faulty
software)
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4683
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-fixed length memory pool
creation error
(Causes of the error message)
1. System software overload (faulty
software)
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4684
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-variable length memory pool
creation error
(Causes of the error message)
1. System software overload (faulty
software)
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4685
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-event creation error
(Causes of the error message)
1. System software overload (faulty
software)
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4686
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-task start error
(Causes of the error message)
1. System software overload (faulty
software)
2. Faulty CPZ23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4687
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-serial Transmission Driver 3
parity error
(Causes of the error message)
1. Noise in electric line
- Outside noise (static electricity,
radio transmission or power
supply-induced)
- Inside noise
2. System software overload (faulty
software)
3. Faulty CPZ23 circuit board (CPU)
1. Click [OK].
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
3. Replace the circuit board.
E-4688
The control for the CPZ circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCPZ-serial Transmission Driver 3
framing error
(Causes of the error message)
1. Noise in electric line
- Outside noise (static electricity,
radio transmission or power
supply-induced)
- Inside noise
2. System software overload (faulty
software)
3. Faulty CPZ23 circuit board (CPU)
1. Click [OK].
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
3. Replace the circuit board.
No.
Message
Factor