7-55
7.3 NC100AY Nest Section
7
Reinstallation
Reinstallation is essentially in the reverse order of
removal.
NOTE: • Tighten the screw while pressing the SSB23 circuit
board counterclockwise.
• Align the phase of the 135/IX240 lane change
• Perform to nest section-to-feed section alignment
adjustment
.
• If the nest section unit has been replaced, perform:
1) 135 entrance guide-to-feed section alignment
2) “Data Writing after Nest Section Unit
Replacement” as described below.
<Data Writing after Nest Section Unit Replacement>
1. Record the “Door close position” and “Door open
position” calibration values indicated in the
parameter sheet attached to the new nest section
unit.
2. Install the carrier to the SP-3000.
3. Open the Menu 0451 “NC100AY Machine Data
Setup” screen.
4. Enter the calibration values in the “Door close
position” and “Door open position” boxes.
5. Click the [Flash ROM Writing] button.
6. Click the [OK] button.
• The entered values are written into the flash
ROM on the CYA23 circuit board.
Z
2
571
SSB23 Circuit Board
Screw
Part No.
Door Close Position
Door Open Position