3.2 Messages and Actions
3
NOTE 1: The refreshing backup can be restored (see Section 3.4).
E-4243
A failure in the GPA circuit board was
detected. (SLOT: ####)
You may continue processing, but the
processing speed will be lowered.
Restart the system. If problems
persist, consult your technical
representative.
(Causes of the error message)
1. Poorly inserted GPA23 circuit
board
2. Faulty GPA23 circuit board
1. Insert the circuit board in the slot
securely.
2. Replace the circuit board.
E-4251
An error occurred in the image
processing section.
Restart the system. If problems
persist, consult your technical
representative.
All DSP downloading failure
(Processing impossible)
(Causes of the error message)
1. Poorly inserted GPA23 circuit
board
2. Faulty GPA23 circuit board
1. Insert the circuit board in the slot
securely.
2. Replace the circuit board.
E-4252
An error occurred in the image
processing section.
Check the print is correctly done.
Incorrect ordered value from scanner
(Software abnormal)
Incorrect ordered HW script
(Abnormal 1394 data or software
abnormal)
(Causes of the error message)
1. Poorly connected or broken 1394
interface cable
2. Abnormal software
3. Poorly inserted GIE23 circuit
board
4. Faulty GIE23 circuit board
1. Connect the cable correctly or
replace it.
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
3. Insert the circuit board correctly in
the slot.
4. Replace the circuit board.
E-4253
The GPA circuit board is not
operable.
Consult your technical
representative.
All DSP delinking/failure
(Causes of the error message)
1. Poorly inserted GPA23 circuit
board
2. Faulty GPA23 circuit board
1. Insert the circuit board in the slot
securely.
2. Replace the circuit board.
I-4254
The GPA circuit board is invalidated.
DSP delinking setup valid
(Maintenance setup)
(Causes of the error message)
1. Incorrect setting
2. Poorly inserted GPA23 circuit
board
3. Faulty GPA23 circuit board
1. Set up DSP Valid/Invalid on Menu
0741 “Image Processing Section
Function Setting”.
2. Insert the circuit board in the slot
securely.
3. Replace the circuit board.
E-4271
The image processing of any frame
was not properly done.
Check the print is correctly done.
Script execution failure (DSP
abnormal response/Sharpness
mixed)
(Causes of the error message)
1. Poorly inserted GPA23 circuit
board
2. Faulty GPA23 circuit board
1. Insert the circuit board in the slot
securely.
2. Replace the circuit board.
E-4272
An error occurred in the image
processing section.
It is possible to continue processing,
but the processing speed will be
lowered.
Cancel failure (Timeout)
(Causes of the error message)
1. Poorly inserted GPA23 circuit
board
2. Faulty GPA23 circuit board
1. Insert the circuit board in the slot
securely.
2. Replace the circuit board.
E-4273
An error occurred in the image
processing section.
You may continue processing, but the
processing speed will be lowered.
DSP reset failure (Faulty DSP/2250
abnormal)
(Causes of the error message)
1. Poorly inserted GPA23 circuit
board
2. Faulty GPA23 circuit board
1. Insert the circuit board in the slot
securely.
2. Replace the circuit board.
No.
Message
Factor