7-84
7.5 Multi-film Carrier MFC10AY (Optional)
Removal
1. Remove the MSB circuit board cover
2. Release the lock of the connector and disconnect
the flexible cable.
3. Disconnect the connector from the circuit board.
4. Remove the four screws and then the circuit
board.
5. Remove the five mask detecting pins.
Installation
Installation is essentially in the reverse order of
removal.
NOTE: Insert the flexible cable into the connector so that its
blue contact area disappears.
Removal
1. Remove the MSB circuit board cover
2. Disconnect the MSB2 connector.
3. Cut the cord tie.
4. Remove the screw and then the solenoid.
Installation
Installation is essentially in the reverse order of
removal.
7.5.4
MSB23 Circuit Board Replacement
Z
2
402
MSB23 Circuit Board
Connector
Screws (4)
Connector
Flexible Cable
Z
2
403
Mask Detecting Pins (5)
7.5.5
Solenoid (S480) Replacement
Z
2
405
Screw
Cord Tie
MSB2 Connector
Solenoid (S480)