7-65
7.3 NC100AY Nest Section
7
4) Pull the slide bracket in the arrow direction and
hold it in such a position that the sensor plate is
placed as far rearward as possible.
Make sure “IPI sensor (D121)” is “Unexposed”.
If it is “Exposed”, proceed to <Detection
Adjustment>.
<Detection Adjustment>
1) Remove the carrier from the SP-3000 with the
IX240 film cartridge inserted.
2) Loosen the IPI sensor fixing screw (yellow
painted).
3) Push the IPI sensor fully toward the rear and
retighten the screw.
4) Install the carrier to the SP-3000.
5) Repeat <Detection Inspection> to make sure “IPI
sensor (D121)” is “Unexposed”.
If it is still “Exposed”, replace the nest unit
(810C1034422) or carrier assembly with a new
one.
Removal
1. Remove the IPI sensor assembly
.
2. Remove the screw and then the cartridge holder
assembly.
Installation
Installation is essentially in the reverse order of
removal.
Z
2
577
IPI Sensor
Sensor Plate
Slide Bracket
Z
2
578
IPI Sensor
Screw (Yellow painted)
Push in Arrow Direction
7.3.12
Cartridge Holder Assembly Replacement
Z
2
355
Screw
Cartridge Holder
Assembly