7 Other Functions
7 - 56
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
The operation of the inverter depends on the Operation Selection at External Operator Disconnection
(b165) setting, when the inverter detects a disconnection (interruption of communications for 5 seconds
or longer) with the Digital Operator.
Use this parameter to select from the following the screen that appears on the Digital Operator at
power-ON. (By factory default, this is set to 001 (d001).)
To enable this function, set the Initial Screen Automatic Return Function (b164) to 01 (Enabled).
When enabled, the function will automatically switch the display to the initial screen if the Digital Opera-
tor is not operated for 10 minutes.
7-6-4
Operation Selection at External Operator Disconnection
Parameter
No.
Function name
Data
Default
data
Unit
b165
Operation Selection at
External Operator Dis-
connection
00:
Trip (E40.
)
02
−
01:
Trip after deceleration stop (E40.
)
02:
Ignore
03:
Free-run stop
04:
Deceleration stop
7-6-5
Initial Screen Selection (Initial Screen after Power-on)
Parameter
No.
Function
name
Data
Content of display (Digital Operator)
Default
data
Unit
b038
Initial Screen
Selection
000
Screen on which the Enter key was last pressed
(Parameters except for d*** and F001)
*1
*1. If you select 000 and turn off the power supply, the inverter will display this parameter (b038) at the next pow-
er-on.
001
−
001
d001 (Output Frequency Monitor)
002
d002 (Output Current Monitor)
003
d003 (RUN Direction Monitor)
:
: (Each data corresponds with d***.)
060
d060 (Inverter Mode Monitor)
201
F001 (Output Frequency Setting/Monitor)
202
Do not set.
7-6-6
Initial Screen Automatic Return Function
Parameter
No.
Function name
Data
Default
data
Unit
b164
Initial Screen Auto-
matic Return Function
00:
Disabled (Automatic return disabled)
00
−
01:
Enabled (Automatic return enabled)
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...