This function causes the inverter stop accelerating/decelerating temporarily and start running at a con-
stant speed at the frequency output at that time.
If the moment of inertia of a load machine is large, you can use it, for example, to have the motor wait
until the amount of motor slip during acceleration/deceleration becomes small. You can use it also to
prevent an overcurrent/overvoltage trip during acceleration/deceleration.
This function works independently of the Acceleration/Deceleration Pattern Selection (A097/A098) set-
ting. It is activated for all acceleration/deceleration patterns by the frequency reference input via the
analog input signal or the optional Digital Operator’s volume control (VR).
There are two acceleration/deceleration stop methods as follows, which can be used in conjunction
with each other.
• Stopping automatically when the specified frequency/stop time is reached
• Stopping by inputting the terminal HLD (83: Retain output frequency) set in the Multi-function Input
S1 to S7 Selection (C001 to C007)
Using this function prolongs the acceleration/deceleration time configured by the F001/F202 and
F003/F203 settings for the duration of the stop time caused by this function.
z
Stopping when the specified frequency/stop time is reached
z
Stopping via input to a multi-function input terminal
7-5-4
Acceleration/Deceleration Stop Function
Parameter
No.
Function name
Data
Default
data
Unit
A069
Acceleration Stop
Frequency
0.00 to Starting Frequency: Disabled
Frequency above Starting Frequency to 400.0
0.00
Hz
A070
Acceleration Stop Time
0.0:
Disabled
0.0
s
0.1 to 60.0
A154
Deceleration Stop
Frequency
0.00 to Starting Frequency: Disabled
Frequency above Starting Frequency to 400.0
0.00
Hz
A155
Deceleration Stop Time
0.0:
Disabled
0.0
s
0.1 to 60.0
C001 to C007
Multi-function Input S1 to
S7 Selection
83:
HLD (Retain output frequency)
−
−
A154
A069
A070
A155
Time
Output frequency
Time
Output frequency
HLD input
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...