![Omron SYSDRIVE MX2 SERIES User Manual Download Page 126](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918126.webp)
3 Operation and Test Run
3 - 18
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
Precautions for Correct Use
The CX-Drive, by default, does not allow connection to the inverter unless the software ver-
sions match.
• Software number of the inverter set in the CX-Drive project
• Software number of inverter actually connected
If you cannot connect to the inverter due to a software number mismatch, select [Tools] -
[Options] in the menu bar and, in the [Online] tab, deselect the [Check Drive Software Compat-
ibility] check box. This allows CX-Drive to connect to the inverter operate normally, although a
warning display appears.
To match the software numbers, right-click on the project, select [Properties], and click the [Set-
tings] button in the [Drive Type] section. In the [Drive Type Settings] window, set the Software
Number that matches that of the inverter. If you cannot find the applicable software number in
the CX-Drive’s Software Number list, please upgrade the CX-Drive version.
Among the projects in the workspace, double-click [Parameter Editor] to open the [Parameter Editor
Window] that shows a list of all inverter parameters (in numeric order).
In this window, you can edit the inverter parameter.
To upload/download parameters from the inverter, use the [Transfer] button in the tool bar.
• Double-click one of the folders under Parameter Editor to narrow down the parameter list to only
those parameters associated with it.
• Edit the value set for each parameter in the Value field of the parameter list.
• When you select a parameter, the explanation of the parameter appears above the parameter list.
• At the left end of the list, icons that represent the status of parameter data are displayed: Not default,
Not default and different from the inverter, or Invalid. You can display only parameters with the same
icon.
• You can select specific parameters and transfer data for only those selected parameters to the inverter.
Editing Parameter Data in CX-Drive
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...