![Omron SYSDRIVE MX2 SERIES User Manual Download Page 569](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918569.webp)
12 - 21
12 Options
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
12-5
DC Reac
tor (
M
ode
l:
3G3AX-D
L
)
12
12-
5-1
S
pecificatio
ns
3-phase
400-V
class
0.4
3G3MX2-
A4004-V1
Heavy load
*1
0.4
1.8
3G3AX-
DL4004
43.0
10
−
10 to 50°C
20% to 90%
At an
altitude of
1,000 m
max.;
indoors
(without
corrosive
gases or
dust)
Light load
0.75
2.1
3G3AX-
DL4007
27.0
0.75
3G3MX2-
A4007-V1
Heavy load
*1
0.75
3.6
Light load
1.5
4.3
3G3AX-
DL4015
14.0
1.5
3G3MX2-
A4015-V1
Heavy load
*1
1.5
5.2
Light load
2.2
5.9
3G3AX-
DL4022
10.1
13
2.2
3G3MX2-
A4022-V1
Heavy load
*1
2.2
6.5
Light load
3.0
8.1
3G3AX-
DL4037
6.4
20
3.0
3G3MX2-
A4030-V1
Heavy load
*1
3.0
7.7
Light load
4.0
9.4
4.0
3G3MX2-
A4040-V1
Heavy load
*1
4.0
11.0
Light load
5.5
13.3
3G3AX-
DL4055
4.41
26
5.5
3G3MX2-
A4055-V1
Heavy load
*1
5.5
16.9
Light load
7.5
20.0
3G3AX-
DL4110
2.33
52
7.5
3G3MX2-
A4075-V1
Heavy load
*1
7.5
18.8
Light load
11
24.0
11
3G3MX2-
A4110-V1
Heavy load
*1
11
29.4
Light load
15
38.0
3G3AX-
DL4150
1.75
60
15
3G3MX2-
A4150-V1
Heavy load
*1
15
35.9
Light load
18.5
44.0
3G3AX-
DL4220
1.2
67
*1. The DC reactor model for the heavy-load mode is selected with reference to the rated current value of a general-purpose motor, which
is 85% of the rated output current of the inverter. If you intend to constantly drive a motor whose rated current value exceeds 85% of the
rated output current of the inverter, use the DC reactor model selected for the light-load mode.
Inverter
DC reactor specifications
Voltage
class
Max.
applicable
motor
capacity [kW]
Model
Heavy/
Light
load
mode
Max.
applicable
motor
capacity [kW]
Rated
input
current
[A]
Model
Inductance
[mH]
Heat
generation
[W]
Operating
ambient
temperature/
humidity
Location
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...