4 Parameter List
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
4-3 Ext
end
ed F
unc
tion
Mod
e
4
4-
3-2 Gro
up b: Det
a
iled Fun
ction Para
meters
*1. The 3G3MX2-V1 Series Inverter does not provide the high-frequency mode.
*2. These parameters are newly added to the 3G3MX2-V1 Series.
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Setting
during
RUN
Changes
during
RUN
Unit
Page
Auxil
iary fu
ncti
on
b145
GS Input Operation
Selection
00: No trip (shut off by hardware)
00
Disabled
Enabled
−
P. 7-98
01: Trip
b150
Inverter Display on
Operator Connec-
tion
001 to 060
(Corresponding to d001 to d060)
001
Enabled
Enabled
−
P. 7-57
b160
User Monitor Selec-
tion 1
001 to 030
(Corresponding to d001 to d030)
001
Enabled
Enabled
−
P. 7-13
b161
User Monitor Selec-
tion 2
001 to 030
(Corresponding to d001 to d030)
002
Enabled
Enabled
−
b163
d001/d007 Data
Setting Selection
00: Disabled
00
Enabled
Enabled
−
P. 7-4
P. 7-6
01: Enabled
b164
Initial Screen Auto-
matic Return Func-
tion
00: Disabled
00
Enabled
Enabled
−
P. 7-56
01: Enabled
b165
Operation Selec-
tion at External
Operator Discon-
nection
00: Trip
02
Enabled
Enabled
−
P. 7-56
01: Trip after deceleration stop
02: Ignore
03: Free-run
stop
04: Deceleration
stop
b166
(Reserved)
Do not change the default 00.
00
−
−
−
−
Mode
b171
Inverter Mode
Selection
00: Selection
disabled
00
Disabled Disabled
−
P. 6-57
01: Induction
motor
02: Do not set.
*1
03: PM
motor
Auxi
liary function
b180
Initialization Exe-
cution
00: Function
disabled
00
Disabled Disabled
−
P. 5-6
01: Execute
initialization
b190
Password A Set-
ting
0000: Function
disabled
0000
Disabled Disabled
−
P. 7-57
0001 to FFFF: Password
b191
Password A for
Authentication
0000 to FFFF
0000
Disabled Disabled
−
b192
Password B Set-
ting
0000: Function
disabled
0000
Disabled Disabled
−
0001 to FFFF: Password
b193
Password B for
Authentication
0000 to FFFF
0000
Disabled Disabled
−
Electroni
c thermal
b910
Motor Electronic
Thermal Selection
*2
00: Disabled
03
Disabled
Enabled
−
P. 7-73
01: Enabled (Fixed subtraction
ratio)
02: Enabled
(b911
subtraction
ratio)
03: Enabled (b912 time parameter
subtraction)
b911
Motor Electronic
Thermal Subtraction
Ratio
*2
0.10 to 100000.00
(Displays upper 4 digits)
600.00
Disabled
Enabled
s
b912
Motor Electronic
Thermal Subtraction
Time Constant
*2
0.10 to 100000.00
(Displays upper 4 digits)
120.00
Disabled
Enabled
s
b913
Motor Electronic
Thermal Integration
Gain
*2
1.0 to 200.0
100.0
Disabled
Enabled
%
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...