![Omron SYSDRIVE MX2 SERIES User Manual Download Page 223](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918223.webp)
5 - 47
5 Basic Settings
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
5-9 Mu
lti-fun
ctio
n
In
pu
t Setting
s
5
5-
9-1 Multi-functio
n Input Select
ion
5-9
Multi-function Input Settings
• You can allocate the functions shown in the following table to the multi-function input terminals S1 to
S7 to use them.
• This section describes seven types of primary functions. For other functions, refer to
7-2
Multi-function Input/Output Functions
on page 7-18.
To allocate the functions, set the values shown in the Data column of the following table in the
Multi-function Input S1 to S7 Selection (C001 to C007).
• Do not allocate the same function to more than one multi-function input terminal. If you allocate the
same function to more than one multi-function input terminal by mistake, the function will be set only
for the terminal to which you allocated last and the previously allocated terminal will be reset to 255
(no: No allocation).
5-9-1
Multi-function Input Selection
Parameter
No.
Data
Function name
Reference item
Page
Multi-function
Input S1 to S7
Selection
(C001 toC007)
00
FW: Forward
Forward run command
P. 5-48
01
RV: Reverse
Reverse run command
P. 5-48
02
CF1: Multi-step speed setting binary 1
Multi-step speed operation
function
P. 5-49
03
CF2: Multi-step speed setting binary 2
04
CF3: Multi-step speed setting binary 3
05
CF4: Multi-step speed setting binary 4
06
JG: Jogging
Jogging
P. 5-52
09
2CH: 2-step acceleration/deceleration
2-step acceleration/deceleration
P. 5-53
18
RS: Reset
Reset
P. 5-53
20
STA: 3-wire start
3-wire input function
P. 5-54
21
STP: 3-wire stop
22
F/R: 3-wire forward/reverse
32
SF1: Multi-step speed setting bit 1
Multi-step speed operation
function
P. 5-49
33
SF2: Multi-step speed setting bit 2
34
SF3: Multi-step speed setting bit 3
35
SF4: Multi-step speed setting bit 4
36
SF5: Multi-step speed setting bit 5
37
SF6: Multi-step speed setting bit 6
38
SF7: Multi-step speed setting bit 7
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...