6 Vector Control and Applied Functions
6 - 38
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
Simple position control has protective functions. Set these functions according to your application.
If the Reset Selection (C102) is set to 02 (Enabled only during trip, default), 00 (Trip reset at power-on),
or 01 (Trip reset at power-off), the current position data is cleared when a trip is reset.
Set the Reset Selection (C102) to 03 (Trip reset only) so as not to clear the current position data.
z
Position control range trip
If the Current Position Monitor (d030) value is out of the position control range specified in the Posi-
tion Limit Setting (P072 and P073), the inverter detects the E83.
(Position control range trip) and
shuts off the output. Set the parameter value according to the moving range for your application.
Because the Digital Operator of this inverter has a 4-digit display, you can set only the upper 4 digits.
To set a value over 4 digits, use the computer tool CX-Drive.
z
Overspeed error detection
If the speed feedback value exceeds the value set in the Overspeed Error Detection Level (P026),
the inverter detects the E81.
(Overspeed error) and shuts off the output.
Set the detection level according to the maximum speed allowable for your application.
z
Speed deviation excessive level detection
If the deviation of the actual frequency from the frequency reference value exceeds the value set in
the Speed Deviation Excessive Level (P027), the inverter outputs the excessive speed deviation sig-
nal (DSE). Although the inverter outputs this signal, it does not shut off its output (trip).
In this case, set the Multi-function Output P1/P2 Selection (C021/C022), or the Multi-function Relay
Output (MA, MB) Function Selection (C026), to 22 (DSE: Excessive speed deviation). In addition,
construct such a sequence that stops the control if the inverter outputs the excessive speed devia-
tion signal (DSE).
P060
Multi-step Position Com-
mand 0
Position range setting (reverse side)
(P073) to position range setting (for-
ward side) (P072)
(Displays upper 4 digits including “
−
”)
(
×
1 multiplication)
0
pulse
P072
Position Limit Setting
(Forward Side)
0 to 268435455
(Displays upper 4 digits)
(
×
1 multiplication)
268435455
pulse
P073
Position Limit Setting
(Reverse Side)
−
268435455 to 0
(Displays upper 4 digits including “
−
”)
(
×
1 multiplication)
−
268435455
pulse
P075
Position Control Mode
Selection
00:
Limit
00
−
01:
No limit
*1
A051
DC Injection Braking Selec-
tion
00:
Disabled
00
−
C021, C022
Multi-function Output P1/P2
Selection
23:
POK (Positioning ready)
−
−
C026
Multi-function Relay Output
(MA, MB) Function Selection
05
−
*1. Refer to
6-7-7 Turntable Control
on page 6-47.
Protective Functions under Simple Position Control
Parameter
No.
Function name
Data
Default data
Unit
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...