![Omron SYSDRIVE MX2 SERIES User Manual Download Page 234](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918234.webp)
5 Basic Settings
5 - 58
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
Precautions for Correct Use
The Multi-function Relay Output (MA, MB) Function Selection (C026) is, by default, set to 05
(AL: Alarm output). However, this default data is based on different alarm output specifications
from those of the previous models (3G3
V Series).
The table below shows the relationship between the relay output status when the inverter input
power supply is ON/OFF and the Multi-function Relay Output (MA, MB) Operation Selection
(C036) setting. Select the parameter setting appropriate to the sequence of your inverter
according to this table.
• This signal is output when the output frequency of the inverter falls below the 0 Hz Detection Level
(C063).
• Allocate one of the Multi-function Output P1/P2 Selection (C021/C022), or the Multi-function Relay
Output (MA, MB) Function Selection (C026), to 21 (ZS).
When the Pulse Train Input RP Selection (P003) is set to 01 (Feedback pulse), this function works
according to the motor rotation speed (feedback value).
Setting in C036
Input
power
supply
Inverter status
Relay output status
Between
MA and MC
Between
MB and MC
00
ON
Normal
Open
Closed
Alarm output
Closed
Open
OFF
−
Open
Closed
01 (Default data)
ON
Normal
Closed
Open
Alarm output
Open
Closed
OFF
−
Open
Closed
Note
Set C036 to 00 to have the same relay output status as with the previous model (3G3
V Series).
5-10-7 0-Hz Detection Signal (ZS)
Parameter
No.
Function name
Data
Default
data
Unit
C021, C022
Multi-function Output P1/P2 Selection
21:
ZS (0 Hz detec-
tion signal)
−
−
C026
Multi-function Relay Output (MA, MB)
Function Selection
05
C063
0 Hz Detection Level
0.00 to 99.99
100.0
0.00
Hz
Related functions
A044, A244, P003
C063
ON
ON
ON
Output frequency
ZS output
RUN command
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...