8 - 13
8 Communications Functions
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
8-
5 Explan
atio
n o
f Each
Fu
nctio
n
C
ode
8
8-5
-3 W
rit
e to Coil [0
5 hex]
z
Response
*1. Broadcasting cannot be performed.
*2. Note that the holding register start address is 0011 hex, which is 1 less than the register number 0012 hex:
Register address = Register number - 1.
*3. Data as much as the number of data bytes will be transferred. In this example, the inverter sends back data
from six holding registers, which is 12 (0C hex) bytes.
Writes the ON/OFF status to a single coil. The coil status changes as shown in the table below.
You need to set the 1st RUN Command Selection (A002) to03 (Modbus communication).
The coil number for the RUN command is 0001.
z
Query
No.
Field name
Example
[hex]
1
Slave address
*1
01
2
Function code
03
3
Number of data bytes
*3
0C
4
Register data 1 (MSB)
00
5
Register data 1 (LSB)
03
6
Register data 2 (MSB)
00
7
Register data 2 (LSB)
04
8
Register data 3 (MSB)
00
9
Register data 3 (LSB)
00
10
Register data 4 (MSB)
04
11
Register data 4 (LSB)
D2
12
Register data 5 (MSB)
01
13
Register data 5 (LSB)
2C
14
Register data 6 (MSB)
0B
15
Register data 6 (LSB)
18
16
CRC-16 (MSB)
D0
17
CRC-16 (LSB)
6D
8-5-3
Write to Coil [05 hex]
Data
Coil status
OFF to ON
ON to OFF
Written data (MSB)
FF hex
00 hex
Written data (LSB)
00 hex
00 hex
Example. Issuing RUN Command to Inverter with Slave Address 1
No.
Field name
Example
[hex]
1
Slave address
*1
01
2
Function code
05
3
Coil address (MSB)
*2
00
4
Coil address (LSB)
*2
00
5
Written data (MSB)
FF
6
Written data (LSB)
00
7
CRC-16 (MSB)
8C
8
CRC-16 (LSB)
3 A
0003 hex
→
03 dec
→
E03 (Factor: Overcurrent)
0004 hex
→
4 dec (Inverter status: During accelera-
tion)
0000 04D2 hex
→
1234 dec
→
12.34 [Hz] (Fre-
quency)
012C hex
→
300 dec
→
3.00 [A] (Current)
0B18 hex
→
2840 dec
→
284.0 [V] (DC voltage)
dec: Decimal
hex: Hexadecimal
(Coil address) = (Coil number)
−
1
OFF to ON: FF00 hex
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...