6 Vector Control and Applied Functions
6 - 56
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
The following parameter selection functions are not available and therefore not displayed on the Digital
Operator.
Switching from the induction motor heavy load mode (default) to the PM motor mode changes the
default data for the following parameter.
Unavailable Selection Functions
Parameter No.
Function name
Unavailable selection functions
b001
Power Interruption/Undervoltage
Restart Selection
04:
Frequency pull-in restart
b008
Overvoltage/Overcurrent Restart
Selection
04:
Frequency pull-in restart
b088
Free-run Stop Selection
02:
Frequency pull-in restart
C001
Multi-function Input S1 Selection
06:
08:
14:
40:
41:
42:
44:
46:
47:
52:
66:
67:
68:
69:
70:
73:
85:
91:
JG (Jogging)
SET (2nd control)
CS (Commercial switching)
TL (Torque limit enabled)
TRQ1 (Torque limit switching 1)
TRQ2 (Torque limit switching 2)
BOK (Brake confirmation)
LAC (LAD cancel)
PCLR (Current position clear)
ATR (Torque reference input permission)
CP1 (Position command selection 1)
CP2 (Position command selection 2)
CP3 (Position command selection 3)
ORL (Origin search limit signal)
ORG (Origin search start signal)
SPD (Speed/Position switching)
EB (Rotation direction detection)
PSET (Preset current position)
C002
Multi-function Input S2 Selection
C003
Multi-function Input S3 Selection
C004
Multi-function Input S4 Selection
C005
Multi-function Input S5 Selection
C006
Multi-function Input S6 Selection
C007
Multi-function Input S7 Selection
C021
Multi-function Output P1 Selection
07:
10:
19:
20:
22:
23:
60:
OTQ (Overtorque/Undertorque signal)
TRQ (Torque limit)
BRK (Brake release)
BER (Brake error)
DSE (Excessive speed deviation)
POK (Position ready)
SETM (Motor 2 selection)
C022
Multi-function Output P2 Selection
C026
Multi-function Relay Output (MA,
MB) Function Selection
C027
MP Selection
02:
Output torque (Only in the sensorless vector control)
C028
AM Selection
02:
Output torque (Only in the sensorless vector control)
11:
Output torque (signed) (Only in the sensorless vec-
tor control)
C103
Reset Restart Selection
02:
Frequency pull-in restart
H001
Auto-tuning Selection
02:
Enabled (Motor rotation)
P003
Pulse Train Input RP Selection
01:
Frequency setting (including PID)
Parameters with Changed Default Data
Parameter No.
Function name
Default data
Initial setting
PM motor mode
b089
Automatic Carrier Reduction
01
00
Summary of Contents for SYSDRIVE MX2 SERIES
Page 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Page 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Page 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...